Research

Electrical Impedance Tomography

Electrical Impedance Tomography (EIT) is a noninvasive tomographic imaging technique that estimates the distribution of electrical properties within a body. EIT systems make electrical stimulations and measure the voltages at combinations of body surface electrodes, from which tomographic images of electrical impeditivity distribution are generated.

Although EIT is no longer a new technology, its use is still in its primary stage. However, global research has drastically increased since its commercial availability, and this has slowly begun to make its way into industry and some areas of medicine.

EIT is a promising method for the development of noninvasive diagnostic medicine, as it is able to provide functional imaging of the body without ionizingg radiation. EIT has several applications in medicine, including but not limited to: Imaging of lung function, Diagnosis of pulmonary embolism, Detection of tumors in the chest area, Diagnosis and distinction of normal and suspected abnormal tissue within the same organ, Bedside monitoring of lung perfusion, Monitoring of a patient’s respiratory function in ways which are not possible through any other means

My research on EIT focuses in many aspects of the technology, among them:

  • Algorithms: Recent research has focused on developing new algorithms to improve the accuracy and speed of EIT imaging
  • Hardware developments: Advances in hardware have led to the development of new EIT systems that are more portable, user-friendly, and cost-effective
  • Clinical applications: EIT has been used in various clinical scenarios, including monitoring respiratory function, cerebral stroke monitoring, and monitoring lung perfusion at the bedside

Inverse problems and ill-posed problems

Inverse problems are mathematical problems that involve calculating the causal factors that produced a set of observations. In other words, given some observed data, the goal is to determine the underlying cause that produced that data. They are important in science and mathematics because they allow us to determine parameters that we cannot directly observe. These types of problems arise in many fields, including physics, astronomy, geophysics, medical imaging, signal processing, and computational 3D imaging.

Here are some examples of inverse problems:

  • Finding the shape of an object from its shadows: This is an example of an inverse problem where we need to find the shape of an object only knowing its shadows (projections)
  • Remote sensing of land or sea from satellite images: Inverse problems can be used to interpret satellite images and determine information about the land or sea
  • Using medical images for diagnosing tumors: Inverse problems can be used to interpret medical images and diagnose tumors
  • Interpreting seismographs to prospect for oil: Inverse problems can be used to interpret seismographs and determine the location of oil deposits

Inverse problems are often ill-posed, meaning that there may be multiple possible solutions or no solution at all. Ill-posed problems are those that lack a unique solution or whose solution is sensitive to small changes in the input data.

Ill-posed inverse problems often requires the use of specific mathematical tools and techniques, such as regularization methods that introduce additional information (prior information) into the problem to obtain stable solutions.

Prior information can come from various sources, such as physical laws, empirical observations, or expert knowledge. In this context, regularization refers to one of the techniques of adding prior information or constraints to the problem. Regularization with prior information can improve the accuracy and stability of the solution and can also help to reduce the computational cost of solving the problem. There are various regularization techniques available, including variational and iterative methods, and recent research has focused on developing adaptive regularization methods that can incorporate prior information in a more flexible and efficient way.

My research focus on building prior information models based on statistical information about the solution.

Cerebral circulation

Cerebral circulation refers to the process of blood flow in the brain, which is responsible for delivering oxygen and nutrients to the brain cells. It is a complex process that involves the interplay between cardiovascular, respiratory, and neural physiology. The cerebral circulation is important because it ensures that the brain receives adequate blood flow, oxygen, and nutrients. It helps maintain cerebral metabolic homeostasis, adequate perfusion, oxygen delivery, and acid-base balance during deviations from homeostasis.

Impaired cerebral circulation can have several consequences, including stroke, vascular cognitive impairment, vascular dementia, motor disorders and disability, disturbed cerebral blood flow regulation and its pathophysiologic sequelae, and increased intracranial pressure due to vasogenic edema.

Cerebral circulation research is a broad field that encompasses the study of blood flow and metabolism in the brain to help the diagnosis and treatment of patients with impaired cerebral circulation. Overall, research on cerebral circulation has important implications for understanding and treating neurological disorders such as strokes. Below I list a few research topics I inverstigate on this subject:

Stroke monitoring

Stroke is a serious life-threateningneurological disorder caused by blockage or rupture of cerebral blood vessels. Stroke is one of the leading causes of death and disability in the world, one fourth of them of working age. Despite advances in acute care of stroke, survivors often have disabilities of various severity, requiring intensive rehabilitation and sometimes even permanent institutional care.

About 80% of strokes are ischemic, caused by a blood clot or atherosclerotic narrowing of the major vessels in the brain. The rest 20% are hemorrhagic strokes, caused by i.e. eruption of small vessels due to atherosclerosis and high blood pressure, malformations of the vessel wall, or thrombolysis/anticoagulation therapy. Despite vigorous efforts, advances in medical therapy of hemorrhagic stroke have remained modest. If growth of hemorrhage is noticed in time, removal of anticoagulants or antithrombotic medication as well as intensive treatment of blood pressure and electrolyte and glucose balance may limit the growth.

Knowledge on the progress of the disease and possible growth of the hemorrhage is crucial during the intensive care. However, monitoring of ICH volume is very challenging, and at present, it is based mainly on clinical signs and neurological assessment of patients. Evaluation of vigilance and awareness of the patient, as well as subtle neurological signs can be very challenging, particularly if the patient is sedated and intubated.

If the patients’ neurological symptoms appear to progress, the only way to control the extent of the intracerebral hemorrhage is to take the patient to computed tomography (CT) scanning. The repeated CT scanning increase radiation dose and form a risk to critically ill patients as they are moved several times from the ICU to CT and back with the life supporting systems. This puts the clinicians into a position, where sometimes only a little can be done to help the patient. Therefore, a bed-side imaging technology that would allow the clinicians to continuously monitor the situation in real-time and allow them to take prophylactic measures before detrimental changes of the brain take place are more than well warranted.

Our solution is based on EIT. In contrast to conventional medical imaging modalities such as CT or MRI, EIT technology is portable allowing bed-side measurements and on-line information about changes in brain tissues. Further, the measurement technology is much cheaper than conventional structural imaging, and thus it would be feasible to monitor every stroke patient in an ICU for possible occurrence of secondary hemorrhage or increase of hemorrhage size. Moreover, EIT is safe because the electrical measurements do not harm the patient (in contrast to, e.g., X-rays in CT imaging).

Aneurysm

In cerebral aneurysm disorders, prompt diversion of blood flow can alleviate the risk of aneurysm rupture and brain haemorrhages. Current strategies to prevent aneurysm rupture commonly involve the use of flow diverters stents (FDS). These are clinically approved wire-braided prostheses that are designed to ‘jail’ the aneurysm at its neck and direct blood flow away from the aneurysm. A significant drawback of this strategy however, is that as well as the aneurysm, FDSs also commonly jail perforating/arterial branches in close proximity to the aneurysm, especially when used to repair aneurysms presenting at bifurcations of the middle cerebral artery (MCA) and anterior communicating arterial complex. Treatment of intracranial aneurysms with FDS procedures can lead to caliber changes of jailed vessels. The reason some branches remain unchanged and others are affected by narrowing remains unknown. The objective of this research is to investigate the influence of local anatomy and resistance to flow from distal vasculature on FDS-­induced hemodynamic modifications affecting bifurcating vessels.

Vasospasm

Cerebral vasospasm (CVS) is a life-threatening condition that occurs in a large proportion of those affected by subarachnoid haemorrhage and stroke. CVS manifests itself as the progressive narrowing of intracranial arteries. It is usually diagnosed using Doppler ultrasound, which quantifies blood velocity changes in the affected vessels, but has low sensitivity when CVS affects the peripheral vasculature. The aim of this study is to identify alternative biomarkers that could be used to diagnose CVS. We use 1D modelling approach to describe the properties of pulse waves that propagate through the cardiovascular system, which allows the effects of different types of vasospasm on waveforms to be characterised at several locations within a simulated cerebral network. The results and methodology of this study have the potential not only to improve the diagnosis and monitoring of vasospasm, but also to be used in the diagnosis of many other cardiovascular diseases where cardiovascular waves can be decoded to provide disease characterisation.

Patient-specific cardiovascular models

Recent improvements in computational tools opened the possibility of patient-specific modeling to aid clinicians during diagnosis, treatment, and monitoring. One example is the modeling of blood flow for surgical planning, where modeling can help predict the prognosis. Computational analysis is used to extract hemodynamic information about the case; however, these methods are sensitive to assumptions on blood properties, boundary conditions, and appropriate geometry accuracy. When available, experimental measurements can be used to validate the results and, among the modalities, ultrasound-based methods are suitable due to their relative low cost and non-invasiveness. This research proposes a procedure to create accurate patient-specific silicone replicas of blood vessels and a power Doppler compatible experimental setup able to simulate and measure realistic flow conditions. The experimental approach offers a setup to quantify flow in in vitro systems and provide more accurate results where other techniques (e.g., particle image velocimetry and particle tracking velocimetry) have shown limitations due to the interference of the interface.

Scroll to Top